Clean Water Oxygen Transfer Testing
In addition to manufacturing and installation services, Aertec provides complete testing and evaluation services for measuring Clean Water Oxygen Transfer, including non-steady state testing for SOTE performance in accordance with the ASCE Standard. Aeration equipment and systems may be tested in situ, factory scale or bench scale.
Click any image to view an enlargement. To exit enlargement view, either click outside the image, hit the "Esc" key or scroll to the bottom of the image and click "Close X."
|
||
Non-Steady State Aeration Test. Oxygen transfer determination for a 1 mgd field-erected pilot plant at a 280 mgd municipal treatment facility.
|
![]() |
First order equation for computing oxygen concentration vs. time in a non-steady state reaeration test. See ASCE Standard [ASCE/EWRI 2-06].
|
||
Data plot of oxygen concentration vs. time in a non-steady state reaction test. |
Oxygen Gas Purity Measurement Device. Oxygen purity analyzer for measuring head-space oxygen content in a closed aeration tank utilizing high purity oxygen gas. |
|
![]() |
|
Winkler analysis for determining dissolved oxygen concentration during a field clean water transfer test. |
Winkler dissolved oxygen test sample |